Hyundai Leistungsschalter MCCB HGP160X 3-polig 100 A

Hyundai MCCB moulded case circuit breaker HGP160X 3P 150kA – 100–160A, adjustable overload and short circuit, IEC 60947-2

100 A
€209,90 EUR incl. VAT €174,92 EUR excl. VAT In stock · ships from our own warehouse · delivery time approx. 4 working days
Skip to product information
Hyundai Leistungsschalter MCCB HGP160X 3-polig 100 A

Hyundai MCCB moulded case circuit breaker HGP160X 3P 150kA – 100–160A, adjustable overload and short circuit, IEC 60947-2

€209,90 EUR incl. VAT €174,92 EUR excl. VAT In stock · ships from our own warehouse · delivery time approx. 4 working days
Shipping calculated at checkout.
HGP160X-G3PT4S0000C00100H
1 left

View store information

Hyundai MCCB moulded case circuit breaker HGP160X 3P 150kA – 100–160A, adjustable overload and short circuit, IEC 60947-2

100 A

Hyundai HGP160X-G-H moulded case circuit breaker (MCCB), 3-pole, 150 kA

The Hyundai HGP160X is a 3-pole moulded case circuit breaker in the 160 AF frame with 150 kA breaking capacity. Overload and short-circuit settings are adjustable separately, so the protection can be matched precisely to cables and loads, for example in sub-distribution boards, machines and plants.

Features

  • Versions 100 and 160 A
  • Short-circuit setting adjustable from 5 to 10 × In
  • Breaking capacity 150 kA at 400/415 V (category X), Ics = 100 % Icu
  • Thermal magnetic trip unit with adjustable overload protection
  • Rated insulation voltage 1,000 V, operational voltage up to 690 V AC
  • Front connection with screw terminals for switchgear and distribution boards
  • Accessories available: auxiliary and alarm switch, shunt and undervoltage release, rotary handle and motor operator

Technical data

ModelHGP160X-G-H
StandardIEC/EN 60947-2, CE
Poles3P
Frame size160 AF
Rated current In100 or 160 A
Trip unitThermal magnetic MTM-25-JJ
Overload setting Ir0,7 – 0,8 – 0,9 – 1,0 × In
Instantaneous setting Ii5 – 6 – 7 – 8 – 9 – 10 × In (adjustable)
Breaking capacity Icu 380/415 V AC150 kA
Breaking capacity Icu 440/460 V AC150 kA
Breaking capacity Icu 480/500 V AC100 kA
Breaking capacity Icu 660/690 V AC10 kA
Breaking capacity Icu 220/240 V AC200 kA
Breaking capacity Icu 250 V DC100 kA
Service breaking capacity Ics100 % Icu
Rated insulation voltage Ui1,000 V
Rated operational voltage Ueup to 690 V AC
Rated impulse withstand voltage Uimp8 kV
Frequency50/60 Hz
Reference temperature40 °C
ConnectionFront connection, screw terminal
Mechanical endurance25,000 operations
Electrical endurance (440 V)10,000 operations
Dimensions (W × H × D)105 × 165 × 86.5 mm
Weight2.0 kg
Matching motor operatorMOT25GP

Installation by a qualified electrician only. Isolate the installation before any work.

Product Safety & Manufacturer Information

Hersteller
HD Hyundai Electric Co., Ltd.
477, Bundangsuseo-ro, Bundang-gu
13553 Seongnam-si, Gyeonggi-do
Republic of Korea

Importeur und verantwortliche Person in der EU
OAM GmbH
Rotenturmstraße 16–18 / 1 / 6th Floor
1010 Vienna, Austria
office@hdeon.com

Produktkennzeichnung
Marke: HD HYUNDAI ELECTRIC
Artikelnummer: HGP160X-G3PT4S0000C00100H
EAN: 8809617407545
CE-gekennzeichnet

Sicherheitshinweise

  • Montage, Anschluss und Inbetriebnahme nur durch eine Elektrofachkraft unter Beachtung der geltenden Errichtungsbestimmungen (z. B. ÖVE/ÖNORM E 8101, DIN VDE 0100).
  • Vor allen Arbeiten die Anlage spannungsfrei schalten, gegen Wiedereinschalten sichern und die Spannungsfreiheit feststellen.
  • Nur innerhalb der angegebenen technischen Daten (Nennspannung, Nennstrom, Schaltvermögen) einsetzen.
  • Beschädigte Geräte nicht installieren oder weiter betreiben. Das Gerät nicht öffnen oder verändern.
  • Montage- und Bedienungsanleitung des Herstellers beachten und aufbewahren.

You might also like