Hyundai Leistungsschalter MCCB HGP100X 3-polig 50 A

Hyundai moulded case circuit breaker HGP100X 3P – adjustable overload, 150 kA, 50–100 A

50 A
€199,90 EUR incl. VAT €166,58 EUR excl. VAT
Skip to product information
Hyundai Leistungsschalter MCCB HGP100X 3-polig 50 A

Hyundai moulded case circuit breaker HGP100X 3P – adjustable overload, 150 kA, 50–100 A

€199,90 EUR incl. VAT €166,58 EUR excl. VAT
Shipping calculated at checkout.
HGP100X-G3PT4S0000C00050F
1 left

View store information

Hyundai moulded case circuit breaker HGP100X 3P – adjustable overload, 150 kA, 50–100 A

50 A

Hyundai HGP100X-G-F moulded case circuit breaker (MCCB), 3-pole, 150 kA

The Hyundai HGP100X is a compact 3-pole moulded case circuit breaker in the 100 AF frame with a very high breaking capacity of 150 kA. It reliably protects cables, distribution boards and loads in commercial and industrial installations against overload and short circuit. The overload setting can be adjusted on the device from 70 to 100 % of the rated current.

Features

  • Versions 50, 63, 80 and 100 A
  • Breaking capacity 150 kA at 400/415 V (category X), Ics = 100 % Icu
  • Thermal magnetic trip unit with adjustable overload protection
  • Rated insulation voltage 1,000 V, operational voltage up to 690 V AC
  • Front connection with screw terminals for switchgear and distribution boards
  • Accessories available: auxiliary and alarm switch, shunt and undervoltage release, rotary handle and motor operator

Technical data

ModelHGP100X-G-F
StandardIEC/EN 60947-2, CE
Poles3P
Frame size100 AF
Rated current In50, 63, 80 or 100 A
Trip unitThermal magnetic MTM-25-JF
Overload setting Ir0,7 – 0,8 – 0,9 – 1,0 × In
Instantaneous setting Ii10 × In (fixed)
Breaking capacity Icu 380/415 V AC150 kA
Breaking capacity Icu 440/460 V AC150 kA
Breaking capacity Icu 480/500 V AC100 kA
Breaking capacity Icu 660/690 V AC10 kA
Breaking capacity Icu 220/240 V AC200 kA
Breaking capacity Icu 250 V DC100 kA
Service breaking capacity Ics100 % Icu
Rated insulation voltage Ui1,000 V
Rated operational voltage Ueup to 690 V AC
Rated impulse withstand voltage Uimp8 kV
Frequency50/60 Hz
Reference temperature40 °C
ConnectionFront connection, screw terminal
Mechanical endurance25,000 operations
Electrical endurance (440 V)10,000 operations
Dimensions (W × H × D)105 × 165 × 86.5 mm
Weight2.0 kg
Matching motor operatorMOT25GP

Installation by a qualified electrician only. Isolate the installation before any work.

Product Safety & Manufacturer Information

Hersteller
HD Hyundai Electric Co., Ltd.
477, Bundangsuseo-ro, Bundang-gu
13553 Seongnam-si, Gyeonggi-do
Republic of Korea

Importeur und verantwortliche Person in der EU
OAM GmbH
Rotenturmstraße 16–18 / 1 / 6th Floor
1010 Vienna, Austria
office@hdeon.com

Produktkennzeichnung
Marke: HD HYUNDAI ELECTRIC
Artikelnummer: HGP100X-G3PT4S0000C00050F
EAN: 8809617402052
CE-gekennzeichnet

Sicherheitshinweise

  • Montage, Anschluss und Inbetriebnahme nur durch eine Elektrofachkraft unter Beachtung der geltenden Errichtungsbestimmungen (z. B. ÖVE/ÖNORM E 8101, DIN VDE 0100).
  • Vor allen Arbeiten die Anlage spannungsfrei schalten, gegen Wiedereinschalten sichern und die Spannungsfreiheit feststellen.
  • Nur innerhalb der angegebenen technischen Daten (Nennspannung, Nennstrom, Schaltvermögen) einsetzen.
  • Beschädigte Geräte nicht installieren oder weiter betreiben. Das Gerät nicht öffnen oder verändern.
  • Montage- und Bedienungsanleitung des Herstellers beachten und aufbewahren.