{"title":"Miniature circuit breakers","description":"\u003cp\u003eHyundai miniature circuit breakers (MCB) protect cables against overload and short circuit. The HGD63P series has a breaking capacity of 10 kA. It is available as 1P, 1P+N, 3P and 3P+N, with curve B or C from 10 to 40 A. Standard: IEC\/EN 60898-1.\u003c\/p\u003e","products":[{"product_id":"hyundai-mcb-leitungsschutzschalter-1p-n-10ka","title":"Hyundai miniature circuit breaker HGD63P 1P+N – curve B, 10 kA, 10–25 A","description":"\u003ch2\u003eHyundai HGD63P Miniature Circuit Breaker 1P+N, 10 kA\u003c\/h2\u003e\u003cp\u003eThe Hyundai HGD63P reliably protects single-phase circuits with phase and neutral conductors against overload and short circuits. The two-pole 1P+N design switches both conductors simultaneously.\u003c\/p\u003e\u003cp\u003eThe 10 kA short-circuit breaking capacity is suitable for installations with higher prospective short-circuit currents. Available in tripping curves B and C, each with 10, 16, 20, or 25 A.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eTwo-pole 1P+N design for phase and neutral conductors\u003c\/li\u003e\n\n\u003cli\u003e10 kA short-circuit breaking capacity\u003c\/li\u003e\n\n\u003cli\u003eTripping curve B or C with 10 to 25 A\u003c\/li\u003e\n\n\u003cli\u003eTrip-free mechanism\u003c\/li\u003e\n\n\u003cli\u003e13-plate arc extinguishing chamber\u003c\/li\u003e\n\n\u003cli\u003eDual terminals for cable and busbar\u003c\/li\u003e\n\n\u003cli\u003ePin and fork busbars suitable\u003c\/li\u003e\n\n\u003cli\u003eOptional AUX, ALT, SHT, UVT, and OVT accessory modules\u003c\/li\u003e\n\n\u003cli\u003eMounting on 35 mm DIN rail\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eAvailable variants\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eCurve B: 10, 16, 20, and 25 A\u003c\/li\u003e\n\n\u003cli\u003eCurve C: 10, 16, 20, and 25 A\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eHGD63P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eReference standard\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 60898-1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1P+N, two-pole\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10, 16, 20, or 25 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e240\/415 V AC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eShort-circuit breaking capacity (Icn)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10 kA, Ics = 75 % Icn\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTripping curves\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eB: 3–5 × In; C: 5–10 × In\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e500 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDielectric strength\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2.5 kV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eElectrical \/ mechanical endurance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10,000 \/ 20,000 operating cycles\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e−40 °C to +55 °C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e95 % RH\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEnergy limiting class\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTerminal capacity (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e25 mm²\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3 g\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40 mm free fall\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eProtection degree\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP20\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eContact indicator\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eRed = ON, Green = OFF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.115 kg per pole, approx. 0.230 kg total\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions per pole (H × D × W)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e81 × 71 × 17.8 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePitch (busbar)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e17.8 mm per pole (1 module), fits standard busbars\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTotal width\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eApprox. 35.6 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eClip-on mounting on DIN rail, 35 × 7.5 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInstallation position\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eVertical or horizontal\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eFlame-retardant thermoplastic\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBusbar connection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003ePin or fork type\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAUX, ALT, SHT, UVT, and OVT available\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"HD HYUNDAI ELECTRIC","offers":[{"title":"10 A","offer_id":58819250815307,"sku":"HGD63P1NMBS0000C00010","price":8.9,"currency_code":"EUR","in_stock":true},{"title":"16 A","offer_id":58819250848075,"sku":"HGD63P1NMBS0000C00016","price":8.9,"currency_code":"EUR","in_stock":true},{"title":"20 A","offer_id":58819250880843,"sku":"HGD63P1NMBS0000C00020","price":8.9,"currency_code":"EUR","in_stock":true},{"title":"25 A","offer_id":58819250913611,"sku":"HGD63P1NMBS0000C00025","price":8.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/9998\/5227\/files\/HGD63P_1PN_B10.png?v=1793638850"},{"product_id":"hyundai-mcb-leitungsschutzschalter-3p-10ka","title":"Hyundai miniature circuit breaker HGD63P 3P – curve C, 10 kA, 10–40 A","description":"\u003ch2\u003eHyundai HGD63P Miniature Circuit Breaker 3P, 10 kA\u003c\/h2\u003e\u003cp\u003eThe three-pole Hyundai HGD63P reliably protects three-phase circuits against overload and short circuits. The short-circuit breaking capacity of 10 kA is suitable for installations with higher prospective short-circuit currents.\u003c\/p\u003e\u003cp\u003eAll offered variants feature the C tripping characteristic and are available in 10, 16, 20, 25, 32, or 40 A. Curve C is suitable for circuits and consumers with increased inrush currents.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eThree-pole design for three-phase circuits\u003c\/li\u003e\n\n\u003cli\u003e10 kA short-circuit breaking capacity\u003c\/li\u003e\n\n\u003cli\u003eCurve C with 10 to 40 A\u003c\/li\u003e\n\n\u003cli\u003eTrip-free mechanism\u003c\/li\u003e\n\n\u003cli\u003e13-plate arc chute\u003c\/li\u003e\n\n\u003cli\u003eDual terminals for cables and busbars\u003c\/li\u003e\n\n\u003cli\u003eSuitable for pin and fork busbars\u003c\/li\u003e\n\n\u003cli\u003eOptional AUX, ALT, SHT, UVT, and OVT accessory modules\u003c\/li\u003e\n\n\u003cli\u003eMounting on 35 mm DIN rail\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eAvailable variants\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eCurve C: 10, 16, 20, 25, 32, and 40 A\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eHGD63P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eReference standard\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 60898-1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10, 16, 20, 25, 32, or 40 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e240\/415 V AC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eShort-circuit breaking capacity (Icn)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10 kA, Ics = 75 % Icn\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTripping characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eC: 5–10 × In\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e500 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDielectric strength\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2.5 kV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eElectrical \/ mechanical endurance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10,000 \/ 20,000 switching cycles\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e−40 °C to +55 °C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e95 % RH\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEnergy limiting class\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eConnection cross-section (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e25 mm²\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3 g\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40 mm free fall\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDegree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP20\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eContact indicator\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eRed = ON, Green = OFF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.115 kg per pole, approx. 0.345 kg total\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions per pole (H × D × W)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e81 × 71 × 17.8 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePitch (busbar)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e17.8 mm per pole (1 module), fits standard busbars\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTotal width\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eApprox. 53.4 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eClip-on mounting on DIN rail, 35 × 7.5 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInstallation position\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eVertical or horizontal\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eFlame-retardant thermoplastic\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBusbar connection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003ePin or fork type\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAUX, ALT, SHT, UVT, and OVT available\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"HD HYUNDAI ELECTRIC","offers":[{"title":"10 A","offer_id":58819254387019,"sku":"HGD63P3PMCS0000C00010","price":18.9,"currency_code":"EUR","in_stock":true},{"title":"16 A","offer_id":58819254419787,"sku":"HGD63P3PMCS0000C00016","price":18.9,"currency_code":"EUR","in_stock":true},{"title":"20 A","offer_id":58819254452555,"sku":"HGD63P3PMCS0000C00020","price":18.9,"currency_code":"EUR","in_stock":true},{"title":"25 A","offer_id":58819254485323,"sku":"HGD63P3PMCS0000C00025","price":18.9,"currency_code":"EUR","in_stock":true},{"title":"32 A","offer_id":58819254518091,"sku":"HGD63P3PMCS0000C00032","price":20.9,"currency_code":"EUR","in_stock":true},{"title":"40 A","offer_id":58819254550859,"sku":"HGD63P3PMCS0000C00040","price":20.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/9998\/5227\/files\/HGD63P3PMCS0000C00010.png?v=1793731402"},{"product_id":"hyundai-mcb-leitungsschutzschalter-1p-10ka","title":"Hyundai miniature circuit breaker HGD63P 1P – curve B, 10 kA, 10–25 A","description":"\u003ch2\u003eHyundai HGD63P Miniature Circuit Breaker 1P, 10 kA\u003c\/h2\u003e\u003cp\u003eThe single-pole Hyundai HGD63P reliably protects electrical circuits from overload and short circuits. The 10 kA short-circuit breaking capacity is suitable for installations with higher prospective short-circuit currents.\u003c\/p\u003e\u003cp\u003eCurve B is available with 10, 16, 20, or 25 A, and curve C is available with 10, 16, 20, 25, or 40 A. Curve B is typically suitable for circuits with low inrush currents, while curve C is for loads with higher inrush currents.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eSingle-pole design with 17.8 mm width\u003c\/li\u003e\n\n\u003cli\u003e10 kA short-circuit breaking capacity\u003c\/li\u003e\n\n\u003cli\u003eTripping curve B or C\u003c\/li\u003e\n\n\u003cli\u003eTrip-free mechanism\u003c\/li\u003e\n\n\u003cli\u003e13-plate arc chute\u003c\/li\u003e\n\n\u003cli\u003eDual terminals for cables and busbars\u003c\/li\u003e\n\n\u003cli\u003eSuitable for pin and fork busbars\u003c\/li\u003e\n\n\u003cli\u003eOptional AUX, ALT, SHT, UVT, and OVT accessory modules\u003c\/li\u003e\n\n\u003cli\u003eMounting on 35 mm DIN rail\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eAvailable variants\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eCurve B: 10, 16, 20, and 25 A\u003c\/li\u003e\n\n\u003cli\u003eCurve C: 10, 16, 20, 25, and 40 A\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eHGD63P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eReference standard\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 60898-1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eDepending on variant 10, 16, 20, 25, or 40 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e240\/415 V AC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eShort-circuit breaking capacity (Icn)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10 kA, Ics = 75% Icn\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTripping curves\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eB: 3–5 × In; C: 5–10 × In\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e500 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDielectric strength\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2.5 kV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eElectrical \/ mechanical lifespan\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10,000 \/ 20,000 switching cycles\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e−40 °C to +55 °C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e95% RH\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEnergy limiting class\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eConnection cross-section (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e25 mm²\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3 g\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40 mm free fall\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP20\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eContact indicator\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eRed = ON, Green = OFF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.115 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × D × W)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e81 × 71 × 17.8 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePitch (busbar)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e17.8 mm per pole (1 module), fits standard busbars\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eClip mounting on DIN rail, 35 × 7.5 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInstallation position\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eVertical or horizontal\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eFlame-retardant thermoplastic\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBusbar connection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003ePin or fork type\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAUX, ALT, SHT, UVT, and OVT available\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"HD HYUNDAI ELECTRIC","offers":[{"title":"10 A","offer_id":58819250422091,"sku":"HGD63P1PMBS0000C00010","price":5.9,"currency_code":"EUR","in_stock":true},{"title":"16 A","offer_id":58819250454859,"sku":"HGD63P1PMBS0000C00016","price":5.9,"currency_code":"EUR","in_stock":true},{"title":"20 A","offer_id":58819250487627,"sku":"HGD63P1PMBS0000C00020","price":5.9,"currency_code":"EUR","in_stock":true},{"title":"25 A","offer_id":58819250520395,"sku":"HGD63P1PMBS0000C00025","price":5.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/9998\/5227\/files\/HGD63P_1P_B10.png?v=1793638850"},{"product_id":"hyundai-mcb-leitungsschutzschalter-3p-n-10ka","title":"Hyundai miniature circuit breaker HGD63P 3P+N – curve B, 10 kA, 10–40 A","description":"\u003ch2\u003eHyundai HGD63P Miniature Circuit Breaker 3P+N, 10 kA\u003c\/h2\u003e\u003cp\u003eThe Hyundai HGD63P reliably protects three-phase circuits with a neutral conductor against overload and short circuits. The 3P+N version is available with rated currents from 10 to 40 A as well as tripping characteristics B or C.\u003c\/p\u003e\u003cp\u003eThe short-circuit breaking capacity of 10 kA is suitable for installations with higher prospective short-circuit currents. The trip-free mechanism ensures that the circuit breaker trips even if the switch lever is held in the ON position.\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eFour-pole 3P+N design\u003c\/li\u003e\n\n\u003cli\u003e10 kA short-circuit breaking capacity\u003c\/li\u003e\n\n\u003cli\u003eVariants with 10, 16, 20, 25, 32, or 40 A\u003c\/li\u003e\n\n\u003cli\u003eTripping curve B or C\u003c\/li\u003e\n\n\u003cli\u003eTrip-free mechanism\u003c\/li\u003e\n\n\u003cli\u003e13-plate arc extinction chamber\u003c\/li\u003e\n\n\u003cli\u003eDual terminals for cables and busbars\u003c\/li\u003e\n\n\u003cli\u003eSuitable for pin and fork busbars\u003c\/li\u003e\n\n\u003cli\u003eOptional AUX, ALT, SHT, UVT, and OVT accessory modules\u003c\/li\u003e\n\n\u003cli\u003eMounting on 35 mm DIN rail\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eTechnical Data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eHGD63P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eReference standard\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 60898-1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3P+N\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10, 16, 20, 25, 32, or 40 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e240\/415 V AC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eShort-circuit breaking capacity (Icn)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10 kA, Ics = 75 % Icn\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTripping characteristics\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eB: 3–5 × In; C: 5–10 × In\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e500 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDielectric strength\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2.5 kV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eElectrical \/ mechanical endurance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10,000 \/ 20,000 operating cycles\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e−40 °C to +55 °C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e95 % RH\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEnergy limiting class\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eConnection cross-section (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e25 mm²\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3 g\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40 mm free fall\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP20\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eContact indicator\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eRed = ON, Green = OFF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.115 kg per pole, approx. 0.460 kg total\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions per pole (H × D × W)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e81 × 71 × 17.8 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePitch (busbar)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e17.8 mm per pole (1 module), fits standard busbars\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTotal width\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eApprox. 71.2 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eClip-on mounting on DIN rail, 35 × 7.5 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInstallation position\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eVertical or horizontal\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eFlame-retardant thermoplastic\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBusbar connection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003ePin or fork type\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAUX, ALT, SHT, UVT, and OVT available\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"HD HYUNDAI ELECTRIC","offers":[{"title":"10 A","offer_id":58819251208523,"sku":"HGD63P3NMBS0000C00010","price":19.9,"currency_code":"EUR","in_stock":true},{"title":"16 A","offer_id":58819251241291,"sku":"HGD63P3NMBS0000C00016","price":19.9,"currency_code":"EUR","in_stock":true},{"title":"20 A","offer_id":58819251274059,"sku":"HGD63P3NMBS0000C00020","price":19.9,"currency_code":"EUR","in_stock":true},{"title":"25 A","offer_id":58819251306827,"sku":"HGD63P3NMBS0000C00025","price":19.9,"currency_code":"EUR","in_stock":true},{"title":"32 A","offer_id":58819251339595,"sku":"HGD63P3NMBS0000C00032","price":21.9,"currency_code":"EUR","in_stock":true},{"title":"40 A","offer_id":58819251372363,"sku":"HGD63P3NMBS0000C00040","price":21.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/9998\/5227\/files\/HGD63P3NMBS0000C00010.png?v=1793638848"},{"product_id":"hyundai-mcb-leitungsschutzschalter-1p-10ka-kennlinie-c","title":"Hyundai miniature circuit breaker HGD63P 1P – curve C, 10 kA, 10–40 A","description":"\u003ch2\u003eHyundai HGD63P 1P Circuit Breaker, 10 kA, Curve C\u003c\/h2\u003e\u003cp\u003eThe single-pole Hyundai HGD63P reliably protects electrical circuits against overload and short circuits. Its short-circuit breaking capacity of 10 kA makes it suitable for installations with higher prospective short-circuit currents.\u003c\/p\u003e\u003cp\u003eThis version features a C tripping characteristic and is available in 10, 16, 20, 25, or 40 A. The curve C is suitable for loads with high inrush currents.\u003c\/p\u003e\u003cp\u003eNeed a curve B? \u003ca href=\"\/en\/products\/hyundai-mcb-leitungsschutzschalter-1p-10ka\"\u003eGo to the curve B version\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eBenefits\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eSingle-pole design with a 17.8 mm width\u003c\/li\u003e\n\n\u003cli\u003e10 kA short-circuit breaking capacity\u003c\/li\u003e\n\n\u003cli\u003eC tripping characteristic\u003c\/li\u003e\n\n\u003cli\u003eAvailable in 10, 16, 20, 25, or 40 A\u003c\/li\u003e\n\n\u003cli\u003eFree-moving mechanism\u003c\/li\u003e\n\n\u003cli\u003e13-part arc extinguishing chamber\u003c\/li\u003e\n\n\u003cli\u003eDual terminals for cables and busbars\u003c\/li\u003e\n\n\u003cli\u003eSuitable for pin and fork busbars\u003c\/li\u003e\n\n\u003cli\u003eOptional AUX, ALT, SHT, UVT, and OVT accessory modules\u003c\/li\u003e\n\n\u003cli\u003eMounting on 35 mm DIN rail\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eAvailable Variants\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eCurve C: 10, 16, 20, 25, and 40 A\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eTechnical Data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eHGD63P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eReference Standard\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 60898-1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10, 16, 20, 25, or 40 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e63 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e240\/415 V AC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Breaking Capacity (Icn)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10 kA, Ics = 75% Icn\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTripping Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eC, magnetic trip at 5–10 × In\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e500 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2.5 kV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eElectrical \/ Mechanical Life\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10,000 \/ 20,000 switching cycles\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e−40 °C to +55 °C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e95% RH\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEnergy Limitation Class\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMax. Connection Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e25 mm²\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3 g\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40 mm free fall\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP20\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eContact Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eRed = ON, Green = OFF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.115 kg\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × D × W)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e81 × 71 × 17.8 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePitch (Phase \/ Fork Busbar)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e17.8 mm per pole (1 TE), suitable for standard phase busbars\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eClip-on mounting on 35 × 7.5 mm DIN rail\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInstallation Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eVertical or horizontal\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eFlame-retardant thermoplastic\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBusbar Connection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003ePin or fork type\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAUX, ALT, SHT, UVT, and OVT available\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"HD HYUNDAI ELECTRIC","offers":[{"title":"10 A","offer_id":58819250585931,"sku":"HGD63P1PMCS0000C00010","price":5.9,"currency_code":"EUR","in_stock":true},{"title":"16 A","offer_id":58819250618699,"sku":"HGD63P1PMCS0000C00016","price":5.9,"currency_code":"EUR","in_stock":true},{"title":"20 A","offer_id":58819250651467,"sku":"HGD63P1PMCS0000C00020","price":5.9,"currency_code":"EUR","in_stock":true},{"title":"25 A","offer_id":58819250684235,"sku":"HGD63P1PMCS0000C00025","price":5.9,"currency_code":"EUR","in_stock":true},{"title":"40 A","offer_id":58819250717003,"sku":"HGD63P1PMCS0000C00040","price":7.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/9998\/5227\/files\/HGD63P_1P_C10.png?v=1793638850"},{"product_id":"hyundai-mcb-leitungsschutzschalter-1p-n-10ka-kennlinie-c","title":"Hyundai miniature circuit breaker HGD63P 1P+N – curve C, 10 kA, 10–25 A","description":"\u003ch2\u003eHyundai HGD63P Circuit Breaker 1P+N, 10 kA, Curve C\u003c\/h2\u003e\u003cp\u003eThe Hyundai HGD63P reliably protects single-phase circuits with phase and neutral conductors against overload and short circuits. The two-pole 1P+N version switches both conductors together.\u003c\/p\u003e\u003cp\u003eThe short-circuit breaking capacity of 10 kA is suitable for installations with higher prospective short-circuit currents. This version has a C tripping characteristic and is available in 10, 16, 20, or 25 A. A curve C is suitable for loads with high inrush currents.\u003c\/p\u003e\u003cp\u003eNeed a curve B? \u003ca href=\"\/en\/products\/hyundai-mcb-leitungsschutzschalter-1p-n-10ka\"\u003eGo to the curve B version\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eTwo-pole 1P+N version for phase and neutral conductors\u003c\/li\u003e\n\n\u003cli\u003e10 kA short-circuit breaking capacity\u003c\/li\u003e\n\n\u003cli\u003eC tripping characteristic available in 10, 16, 20, or 25 A\u003c\/li\u003e\n\n\u003cli\u003eFree-moving mechanism\u003c\/li\u003e\n\n\u003cli\u003e13-part arc extinguishing chamber\u003c\/li\u003e\n\n\u003cli\u003eDual terminals for cable and busbar\u003c\/li\u003e\n\n\u003cli\u003eSuitable for pin and fork busbars\u003c\/li\u003e\n\n\u003cli\u003eOptional AUX, ALT, SHT, UVT, and OVT accessory modules\u003c\/li\u003e\n\n\u003cli\u003eMounting on 35 mm DIN rail\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eAvailable Variants\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eCurve C: 10, 16, 20, and 25 A\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eTechnical Data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eHGD63P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eReference Standard\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 60898-1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e1P+N, two-pole\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10, 16, 20, or 25 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e63 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e240\/415 V AC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Breaking Capacity (Icn)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10 kA, Ics = 75% Icn\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTripping Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eC, magnetic trip at 5–10 × In\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e500 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2.5 kV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eElectrical \/ Mechanical Life\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10,000 \/ 20,000 switching cycles\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e−40 °C to +55 °C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e95% RH\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEnergy Limiting Class\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eConnection Cross-Section (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e25 mm²\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3 g\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40 mm free fall\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP20\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eContact Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eRed = ON, Green = OFF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.115 kg per pole, approx. 0.230 kg total\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions per Pole (H × D × W)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e81 × 71 × 17.8 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePitch (Phase \/ Fork Busbar)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e17.8 mm per pole (1 TE), suitable for standard phase busbars\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTotal Width\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eApprox. 35.6 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eClip-on mounting on DIN rail, 35 × 7.5 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInstallation Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eVertical or horizontal\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eFlame-retardant thermoplastic\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBusbar Connection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003ePin or fork type\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAUX, ALT, SHT, UVT, and OVT available\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"HD HYUNDAI ELECTRIC","offers":[{"title":"10 A","offer_id":58819251011915,"sku":"HGD63P1NMCS0000C00010","price":8.9,"currency_code":"EUR","in_stock":true},{"title":"16 A","offer_id":58819251044683,"sku":"HGD63P1NMCS0000C00016","price":8.9,"currency_code":"EUR","in_stock":true},{"title":"20 A","offer_id":58819251077451,"sku":"HGD63P1NMCS0000C00020","price":8.9,"currency_code":"EUR","in_stock":true},{"title":"25 A","offer_id":58819251110219,"sku":"HGD63P1NMCS0000C00025","price":8.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/9998\/5227\/files\/HGD63P_1PN_C10.png?v=1793638851"},{"product_id":"hyundai-mcb-leitungsschutzschalter-3p-n-10ka-kennlinie-c","title":"Hyundai miniature circuit breaker HGD63P 3P+N – curve C, 10 kA, 10–40 A","description":"\u003ch2\u003eHyundai HGD63P 3P+N Circuit Breaker, 10 kA, Curve C\u003c\/h2\u003e\u003cp\u003eThe Hyundai HGD63P reliably protects three-phase circuits with a neutral conductor against overload and short circuits. The 3P+N version has a C tripping characteristic and is available in 10, 16, 20, 25, 32, or 40 A. The curve C is suitable for loads with high inrush currents.\u003c\/p\u003e\u003cp\u003eThe short-circuit breaking capacity of 10 kA is suitable for installations with higher prospective short-circuit currents. The free-release mechanism ensures that the circuit breaker trips even when the operating lever is held in the ON position.\u003c\/p\u003e\u003cp\u003eNeed a curve B? \u003ca href=\"\/en\/products\/hyundai-mcb-leitungsschutzschalter-3p-n-10ka\"\u003eGo to the curve B version\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eAdvantages\u003c\/h3\u003e\u003cul\u003e\n\n\u003cli\u003eFour-pole 3P+N version\u003c\/li\u003e\n\n\u003cli\u003e10 kA short-circuit breaking capacity\u003c\/li\u003e\n\n\u003cli\u003eVariants in 10, 16, 20, 25, 32, or 40 A\u003c\/li\u003e\n\n\u003cli\u003eC tripping characteristic\u003c\/li\u003e\n\n\u003cli\u003eFree-release mechanism\u003c\/li\u003e\n\n\u003cli\u003e13-part arc extinguishing chamber\u003c\/li\u003e\n\n\u003cli\u003eDual terminals for cable and busbar\u003c\/li\u003e\n\n\u003cli\u003eSuitable for pin and fork busbars\u003c\/li\u003e\n\n\u003cli\u003eOptional AUX, ALT, SHT, UVT, and OVT accessory modules\u003c\/li\u003e\n\n\u003cli\u003eMounting on 35 mm DIN rail\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\u003ch3\u003eTechnical Data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eHGD63P\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eReference Standard\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIEC\/EN 60898-1\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3P+N\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated Current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10, 16, 20, 25, 32, or 40 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e63 A\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e240\/415 V AC\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Breaking Capacity (Icn)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10 kA, Ics = 75% Icn\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTripping Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eC, magnetic trip at 5–10 × In\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e500 V\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2.5 kV\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eElectrical \/ Mechanical Life\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e10,000 \/ 20,000 switching cycles\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e−40 °C to +55 °C\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e95% RH\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eEnergy Limiting Class\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eConductor Cross-Section (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e25 mm²\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e3 g\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e40 mm free fall\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eIP20\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eContact Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eRed = ON, Green = OFF\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e0.115 kg per pole, approx. 0.460 kg total\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eDimensions per Pole (H × D × W)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e81 × 71 × 17.8 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003ePitch (Phase \/ Fork Busbar)\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003e17.8 mm per pole (1 TE), suitable for standard phase busbars\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eTotal Width\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eApprox. 71.2 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eClip-on mounting on DIN rail, 35 × 7.5 mm\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eInstallation Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eVertical or horizontal\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eFlame-retardant thermoplastic\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eBusbar Connection\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003ePin or fork type\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/td\u003e\n\n\u003ctd\u003eAUX, ALT, SHT, UVT, and OVT available\u003c\/td\u003e\n\n\n\u003c\/tr\u003e\n\n\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"HD HYUNDAI ELECTRIC","offers":[{"title":"10 A","offer_id":58819251405131,"sku":"HGD63P3NMCS0000C00010","price":19.9,"currency_code":"EUR","in_stock":true},{"title":"16 A","offer_id":58819251437899,"sku":"HGD63P3NMCS0000C00016","price":19.9,"currency_code":"EUR","in_stock":true},{"title":"20 A","offer_id":58819251470667,"sku":"HGD63P3NMCS0000C00020","price":19.9,"currency_code":"EUR","in_stock":true},{"title":"25 A","offer_id":58819251503435,"sku":"HGD63P3NMCS0000C00025","price":19.9,"currency_code":"EUR","in_stock":true},{"title":"32 A","offer_id":58819251536203,"sku":"HGD63P3NMCS0000C00032","price":21.9,"currency_code":"EUR","in_stock":true},{"title":"40 A","offer_id":58819251568971,"sku":"HGD63P3NMCS0000C00040","price":21.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/9998\/5227\/files\/HGD63P3NMCS0000C00010.png?v=1793638848"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/9998\/5227\/collections\/MCB_1P_Upscaled_9344e43a-7484-456b-b272-5f5df3ee4628.png?v=1794748164","url":"https:\/\/hdeon.com\/en\/collections\/leitungsschutzschalter-mcb.oembed","provider":"HDEON","version":"1.0","type":"link"}