{"title":"Circuit breakers \u0026 accessories","description":"\u003cp\u003eHyundai moulded case circuit breakers (MCCB) of the HGP series, 3-pole, from 50 to 400 A. With a breaking capacity of 150 kA at 400 V they protect incoming feeders, sub-distributions and large outgoing circuits against overload and short circuit. The overload release is adjustable on all devices, from the HGP160X onwards the short-circuit release as well. HGP100X, HGP160X and HGP250X share the same compact frame, the HGP400X is the larger frame. Phase barriers and screws are included. Datasheet and package leaflet (German) can be downloaded on every product page. Matching motor operators MOT25GP and MOT63GP for remote switching on and off are also available.\u003c\/p\u003e","products":[{"product_id":"hyundai-mccb-leistungsschalter-hgp100x-3p","title":"Hyundai moulded case circuit breaker HGP100X 3P – adjustable overload, 150 kA, 50–100 A","description":"\u003ch2\u003eHyundai HGP100X-G-F moulded case circuit breaker (MCCB), 3-pole, 150 kA\u003c\/h2\u003e\u003cp\u003eThe Hyundai HGP100X is a compact 3-pole moulded case circuit breaker in the 100 AF frame with a very high breaking capacity of 150 kA. It reliably protects cables, distribution boards and loads in commercial and industrial installations against overload and short circuit. The overload setting can be adjusted on the device from 70 to 100 % of the rated current.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eVersions 50, 63, 80 and 100 A\u003c\/li\u003e\u003cli\u003eBreaking capacity 150 kA at 400\/415 V (category X), Ics = 100 % Icu\u003c\/li\u003e\u003cli\u003eThermal magnetic trip unit with adjustable overload protection\u003c\/li\u003e\u003cli\u003eRated insulation voltage 1,000 V, operational voltage up to 690 V AC\u003c\/li\u003e\u003cli\u003eFront connection with screw terminals for switchgear and distribution boards\u003c\/li\u003e\u003cli\u003eAccessories available: auxiliary and alarm switch, shunt and undervoltage release, rotary handle and motor operator\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHGP100X-G-F\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eIEC\/EN 60947-2, CE\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e3P\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFrame size\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100 AF\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRated current In\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e50, 63, 80 or 100 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eThermal magnetic MTM-25-JF\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eOverload setting Ir\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e0,7 – 0,8 – 0,9 – 1,0 × In\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eInstantaneous setting Ii\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e10 × In (fixed)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 380\/415 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e150 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 440\/460 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e150 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 480\/500 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 660\/690 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e10 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 220\/240 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e200 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 250 V DC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eService breaking capacity Ics\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100 % Icu\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRated insulation voltage Ui\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e1,000 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRated operational voltage Ue\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eup to 690 V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage Uimp\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e8 kV\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference temperature\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e40 °C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eFront connection, screw terminal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMechanical endurance\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e25,000 operations\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eElectrical endurance (440 V)\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e10,000 operations\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e105 × 165 × 86.5 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e2.0 kg\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMatching motor operator\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eMOT25GP\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eInstallation by a qualified electrician only. Isolate the installation before any work.\u003c\/p\u003e","brand":"HD HYUNDAI ELECTRIC","offers":[{"title":"50 A","offer_id":59268637720907,"sku":"HGP100X-G3PT4S0000C00050F","price":199.9,"currency_code":"EUR","in_stock":true},{"title":"63 A","offer_id":59268637753675,"sku":"HGP100X-G3PT4S0000C00063F","price":199.9,"currency_code":"EUR","in_stock":true},{"title":"80 A","offer_id":59268637786443,"sku":"HGP100X-G3PT4S0000C00080F","price":199.9,"currency_code":"EUR","in_stock":true},{"title":"100 A","offer_id":59268637819211,"sku":"HGP100X-G3PT4S0000C00100F","price":199.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/9998\/5227\/files\/HD_Hyundai_MCCB_HGP100X_50A.png?v=1794646774"},{"product_id":"hyundai-mccb-leistungsschalter-hgp160x-3p","title":"Hyundai moulded case circuit breaker HGP160X 3P – adjustable overload + short circuit, 150 kA, 100–160 A","description":"\u003ch2\u003eHyundai HGP160X-G-H moulded case circuit breaker (MCCB), 3-pole, 150 kA\u003c\/h2\u003e\u003cp\u003eThe Hyundai HGP160X is a 3-pole moulded case circuit breaker in the 160 AF frame with 150 kA breaking capacity. Overload and short-circuit settings are adjustable separately, so the protection can be matched precisely to cables and loads, for example in sub-distribution boards, machines and plants.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eVersions 100 and 160 A\u003c\/li\u003e\u003cli\u003eShort-circuit setting adjustable from 5 to 10 × In\u003c\/li\u003e\u003cli\u003eBreaking capacity 150 kA at 400\/415 V (category X), Ics = 100 % Icu\u003c\/li\u003e\u003cli\u003eThermal magnetic trip unit with adjustable overload protection\u003c\/li\u003e\u003cli\u003eRated insulation voltage 1,000 V, operational voltage up to 690 V AC\u003c\/li\u003e\u003cli\u003eFront connection with screw terminals for switchgear and distribution boards\u003c\/li\u003e\u003cli\u003eAccessories available: auxiliary and alarm switch, shunt and undervoltage release, rotary handle and motor operator\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHGP160X-G-H\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eIEC\/EN 60947-2, CE\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e3P\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFrame size\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e160 AF\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRated current In\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100 or 160 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eThermal magnetic MTM-25-JJ\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eOverload setting Ir\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e0,7 – 0,8 – 0,9 – 1,0 × In\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eInstantaneous setting Ii\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e5 – 6 – 7 – 8 – 9 – 10 × In (adjustable)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 380\/415 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e150 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 440\/460 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e150 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 480\/500 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 660\/690 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e10 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 220\/240 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e200 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 250 V DC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eService breaking capacity Ics\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100 % Icu\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRated insulation voltage Ui\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e1,000 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRated operational voltage Ue\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eup to 690 V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage Uimp\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e8 kV\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference temperature\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e40 °C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eFront connection, screw terminal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMechanical endurance\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e25,000 operations\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eElectrical endurance (440 V)\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e10,000 operations\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e105 × 165 × 86.5 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e2.0 kg\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMatching motor operator\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eMOT25GP\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eInstallation by a qualified electrician only. Isolate the installation before any work.\u003c\/p\u003e","brand":"HD HYUNDAI ELECTRIC","offers":[{"title":"100 A","offer_id":59268637884747,"sku":"HGP160X-G3PT4S0000C00100H","price":209.9,"currency_code":"EUR","in_stock":true},{"title":"160 A","offer_id":59268637917515,"sku":"HGP160X-G3PT4S0000C00160H","price":209.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/9998\/5227\/files\/HD_Hyundai_MCCB_HGP160X_100A.png?v=1794646775"},{"product_id":"hyundai-mccb-leistungsschalter-hgp250x-3p","title":"Hyundai moulded case circuit breaker HGP250X 3P – adjustable overload + short circuit, 150 kA, 160–250 A","description":"\u003ch2\u003eHyundai HGP250X-G-H moulded case circuit breaker (MCCB), 3-pole, 150 kA\u003c\/h2\u003e\u003cp\u003eThe Hyundai HGP250X is a 3-pole moulded case circuit breaker in the 250 AF frame with 150 kA breaking capacity – in the same compact housing as the HGP100 and HGP160. Overload and short-circuit settings are adjustable separately. Typical applications are main distribution boards, incoming feeders and larger machines.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eVersions 160 and 250 A\u003c\/li\u003e\u003cli\u003eShort-circuit setting adjustable from 5 to 10 × In\u003c\/li\u003e\u003cli\u003eBreaking capacity 150 kA at 400\/415 V (category X), Ics = 100 % Icu\u003c\/li\u003e\u003cli\u003eThermal magnetic trip unit with adjustable overload protection\u003c\/li\u003e\u003cli\u003eRated insulation voltage 1,000 V, operational voltage up to 690 V AC\u003c\/li\u003e\u003cli\u003eFront connection with screw terminals for switchgear and distribution boards\u003c\/li\u003e\u003cli\u003eAccessories available: auxiliary and alarm switch, shunt and undervoltage release, rotary handle and motor operator\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHGP250X-G-H\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eIEC\/EN 60947-2, CE\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e3P\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFrame size\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e250 AF\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRated current In\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e160 or 250 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eThermal magnetic MTM-25-JJ\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eOverload setting Ir\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e0,7 – 0,8 – 0,9 – 1,0 × In\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eInstantaneous setting Ii\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e5 – 6 – 7 – 8 – 9 – 10 × In (adjustable)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 380\/415 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e150 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 440\/460 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e150 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 480\/500 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 660\/690 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e10 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 220\/240 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e200 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 250 V DC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eService breaking capacity Ics\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100 % Icu\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRated insulation voltage Ui\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e1,000 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRated operational voltage Ue\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eup to 690 V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage Uimp\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e8 kV\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference temperature\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e40 °C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eFront connection, screw terminal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMechanical endurance\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e25,000 operations\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eElectrical endurance (440 V)\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e10,000 operations\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e105 × 165 × 86.5 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e2.0 kg\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMatching motor operator\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eMOT25GP\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eInstallation by a qualified electrician only. Isolate the installation before any work.\u003c\/p\u003e","brand":"HD HYUNDAI ELECTRIC","offers":[{"title":"160 A","offer_id":59268637950283,"sku":"HGP250X-G3PT4S0000C00160H","price":229.9,"currency_code":"EUR","in_stock":true},{"title":"250 A","offer_id":59268637983051,"sku":"HGP250X-G3PT4S0000C00250H","price":229.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/9998\/5227\/files\/HD_Hyundai_MCCB_HGP250X_160A.png?v=1794646775"},{"product_id":"hyundai-mccb-leistungsschalter-hgp400x-3p","title":"Hyundai moulded case circuit breaker HGP400X 3P – adjustable overload + short circuit, 150 kA, 300–400 A","description":"\u003ch2\u003eHyundai HGP400X-H moulded case circuit breaker (MCCB), 3-pole, 150 kA\u003c\/h2\u003e\u003cp\u003eThe Hyundai HGP400X is a 3-pole moulded case circuit breaker in the 400 AF frame with 150 kA breaking capacity for incoming feeders and main distribution boards with high currents. Overload and short-circuit settings are adjustable separately.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eVersions 300 and 400 A\u003c\/li\u003e\u003cli\u003eShort-circuit setting adjustable from 5 to 10 × In\u003c\/li\u003e\u003cli\u003e35 kA even at 660\/690 V AC\u003c\/li\u003e\u003cli\u003eBreaking capacity 150 kA at 400\/415 V (category X), Ics = 100 % Icu\u003c\/li\u003e\u003cli\u003eThermal magnetic trip unit with adjustable overload protection\u003c\/li\u003e\u003cli\u003eRated insulation voltage 1,000 V, operational voltage up to 690 V AC\u003c\/li\u003e\u003cli\u003eFront connection with screw terminals for switchgear and distribution boards\u003c\/li\u003e\u003cli\u003eAccessories available: auxiliary and alarm switch, shunt and undervoltage release, rotary handle and motor operator\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eHGP400X-H\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eIEC\/EN 60947-2, CE\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e3P\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFrame size\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e400 AF\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRated current In\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e300 or 400 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eTrip unit\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eThermal magnetic MTM-63-JJ\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eOverload setting Ir\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e0,8 – 0,9 – 1,0 × In\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eInstantaneous setting Ii\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e5 – 6 – 7 – 8 – 9 – 10 × In (adjustable)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 380\/415 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e150 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 440\/460 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e150 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 480\/500 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 660\/690 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e35 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 220\/240 V AC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e200 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eBreaking capacity Icu 250 V DC\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eService breaking capacity Ics\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e100 % Icu\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRated insulation voltage Ui\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e1,000 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRated operational voltage Ue\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eup to 690 V AC\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage Uimp\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e8 kV\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eReference temperature\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e40 °C\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eFront connection, screw terminal\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMechanical endurance\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e20,000 operations\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eElectrical endurance (440 V)\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e6,000 operations\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e140 × 260 × 110 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e5.4 kg\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eMatching motor operator\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eMOT63GP\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eInstallation by a qualified electrician only. Isolate the installation before any work.\u003c\/p\u003e","brand":"HD HYUNDAI ELECTRIC","offers":[{"title":"300 A","offer_id":59268638179659,"sku":"HGP400X3PT4S0000C00300H","price":539.9,"currency_code":"EUR","in_stock":true},{"title":"400 A","offer_id":59268638212427,"sku":"HGP400X3PT4S0000C00400H","price":539.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/9998\/5227\/files\/HD_Hyundai_MCCB_HGP400X_300A.png?v=1794646772"},{"product_id":"hyundai-motorantrieb-mot25gp-leistungsschalter","title":"Hyundai motor operator MOT25GP – AC\/DC 240 V, for HGP100X–HGP250X","description":"\u003ch2\u003eHyundai motor operator MOT25GP for circuit breakers HGP100\/160\/250\u003c\/h2\u003e\u003cp\u003eThe motor operator MOT25GP switches the Hyundai circuit breakers HGP100\/160\/250 ON and OFF remotely. It is ideal for automated low-voltage systems, load shedding and changeover to emergency power.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eRemote ON\/OFF via AC\/DC 240 V control voltage\u003c\/li\u003e\u003cli\u003eAuto\/manual selector, manual operation possible at any time\u003c\/li\u003e\u003cli\u003eMounted directly on the circuit breaker\u003c\/li\u003e\u003cli\u003eEndurance 10,000 operations\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eMOT25GP\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eSuitable for\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eCircuit breakers HGP100\/160\/250, 3- and 4-pole\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eControl voltage\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eAC\/DC 240 V (range 85–110 %)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eOperating current\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e≤ 0.5 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eClosing time\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e≤ 1,000 ms\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eOpening time\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e≤ 1,000 ms\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e14 W\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eEndurance\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e10,000 operations\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eRemote ON\/OFF, auto\/manual selector, manual operation possible\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eMounting note: only fit the motor operator when the breaker handle is in the OFF position. Installation by a qualified electrician only.\u003c\/p\u003e","brand":"HD HYUNDAI ELECTRIC","offers":[{"title":"Default Title","offer_id":59268645716299,"sku":"MOT25GP-AC\/DC240V","price":249.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/9998\/5227\/files\/HD_Hyundai_Motorantrieb_MOT25GP_vorne.png?v=1794646775"},{"product_id":"hyundai-motorantrieb-mot63gp-leistungsschalter","title":"Hyundai motor operator MOT63GP – AC\/DC 240 V, for HGP400X","description":"\u003ch2\u003eHyundai motor operator MOT63GP for circuit breakers HGP400\/630\u003c\/h2\u003e\u003cp\u003eThe motor operator MOT63GP switches the Hyundai circuit breakers HGP400\/630 ON and OFF remotely. It is ideal for automated low-voltage systems, load shedding and changeover to emergency power.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eRemote ON\/OFF via AC\/DC 240 V control voltage\u003c\/li\u003e\u003cli\u003eAuto\/manual selector, manual operation possible at any time\u003c\/li\u003e\u003cli\u003eMounted directly on the circuit breaker\u003c\/li\u003e\u003cli\u003eEndurance 5,000 operations\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eMOT63GP\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eSuitable for\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eCircuit breakers HGP400\/630, 3- and 4-pole\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eControl voltage\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eAC\/DC 240 V (range 85–110 %)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eOperating current\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e≤ 2.0 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eClosing time\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e≤ 1,200 ms\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eOpening time\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e≤ 1,200 ms\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e35 W\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eEndurance\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003e5,000 operations\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\u003ctd\u003eRemote ON\/OFF, auto\/manual selector, manual operation possible\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003eMounting note: only fit the motor operator when the breaker handle is in the OFF position. Installation by a qualified electrician only.\u003c\/p\u003e","brand":"HD HYUNDAI ELECTRIC","offers":[{"title":"Default Title","offer_id":59268646338891,"sku":"MOT63GP-AC\/DC240V","price":409.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/9998\/5227\/files\/HD_Hyundai_Motorantrieb_MOT63GP_vorne.png?v=1794646775"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1050\/9998\/5227\/collections\/HD_Hyundai_MCCB_HGP_Baugroesse_100-250AF.png?v=1794568758","url":"https:\/\/hdeon.com\/en\/collections\/leistungsschalter-mccb.oembed","provider":"HDEON","version":"1.0","type":"link"}